Disarm: Enter Code (If you are still in exit time, just press [CLEAR] to disarm.)
Check Faulted Zones: Faulted zones display automatically when faulted.
Bypass Zone(s): Press [Zone #] + [*].
Smoke Reset: After silencing siren by entering code, press [3] + code to reset smokes.
* If smoke has not cleared the alarm may resound. Clear the detector of smoke and repeat the sequence to reset.
Chime Mode On/Off: Press [7], keypad will display current setting.
To Change, enter code + [1] to turn off, [2] to turn on short beep, [3] to beep until CLEAR key is pressed, or [4] to beep until point closes.
Code Change: It is recommended that you contact your security company and make changes under their direction.
Enter [5], + [Old Code] + [New Code] same # of digits as old code, + [New Code] again.
Power Down Panel: Pull wire on NP7-12 battery. Then unplug the panel transformer if you know where it is. It is a beige box plugged into a nearby power outlet. If you can’t find it, then disconnect AC wire, upper left terminal on board.
User Manual: D202A Manual